伺服器PSU顯示錯誤訊息

Issue Description

By removing power supply from the server, the LED from the equipment don’t reporting an error and also, not iBMC reports any problems.

If the power cable is diconnected from the server, LED and iBMC reports a problem. 

Solution

When the power cable is removed from PSU, the sensor from the server generate an error that the PSU has some issue (like a faulty PSU). If the PSU is removed from the server, the sensor from the server feels that the PSU is not present physically and this event can be generated only by the human intervention.